Controllers for Teddington Air Curtain systems

Intuitive and user-friendly

Air Curtain systems must switch on when they are needed. That's why we offer customized control systems for individual requirements on site. The most important thing: installation and operation are intuitive and user-friendly.

  • Controllers specifically for Shop & Business or industrial applications
  • Can be integrated into the existing building management system (BMS)
  • Multi-master solutions – one control panel for several independently controlled Air Curtain units
  • Fully automatic solutions – once set, the system runs automatically all year round depending on the temperatures
Shop & Business, Design

Controllers for our Shop & Business and Design Air Curtains

Broad controller portfolio

Modern and fast-responding touchscreen for our TCX controller

Controllers for the basic functions of the Air Curtains (TSC 5 and TSC 3-E)

Integration into Modbus or BACnet networks via the TCX Ethernet module with control panel

Full functionality via Modbus RTU without control panel

Controllers for water-heated Air Curtain systems

Teddington TCX control unit

TCX

Modern and intuitive touch control

Teddington air curtain Ethernet module

Ethernet module (TCX)

Integration into Modbus or BACnet networks via the TCX Ethernet module with control panel

Teddington TCX lite control unit

TCX Lite

Compact control unit for installation in flush-mounted boxes and a switch programme

Teddington TSC5 control unit

TSC 5

Easy-to-operate control for the basic functions of the Air Curtain

Controllers for electrical heated Air Curtain systems

Teddington TCX control unit

TCX-E

Modern and intuitive touch control for electrically heated systems

Teddington air curtain Ethernet module

Ethernet module (TCX)

Integration into Modbus or BACnet networks via the TCX Ethernet module with control panel

Teddington TSC3-E control unit

TSC 3-E

Easy-to-operate control for the basic functions of the electrically heated Air Curtain

Functions of our shop & business controllers

Functions TCX TCX Lite TSC 5 TCX-E TSC 3-E
Heating mediumWater heaterWater heaterWater heaterElectric heaterElectric heater
Air volume control5-stage (AC)5-stage (AC)5-stage (AC)3-stage (AC)3-stage (AC)
stepless (EC)stepless (EC)stepless (EC)stepless (EC)stepless (EC)
Key lock
External release
Summer / winter function
Manual / Automatic Function
Room thermostat
Room sensor
Potential-free operating and fault message
*1
*2
*1
Integrated weekly timer
After-run function
Filter monitoring
Operating hours counter
Fault memory
Speed control from the BMS
Electrical discharge temperature control
Expandable with Ethernet module
Multi-master function
Menu languages1010
10

*1 = potential-free operating message only
*2 = potential-free operating and fault message only for EC motors, 0 - 10 V signal for AC motors

The most important functions explained

External release:

The device is enabled by a BMS via external enable. The external release takes place via a potential-free contact.

To overview

Summer / winter function:

It is easy to switch between summer and winter mode via the control unit.

In summer mode, all connected heating valves are closed. The air curtain then operates in ambient mode.

In winter mode, shut-off valves are opened and control valves resume normal operation. The discharged air is heated accordingly.

To overview

Manual / Automatic-Function:

It is easy to switch between manual and automatic mode via the control unit.

In manual mode, the Air Curtain system runs independently of automatic signals (e.g. door contact).

In automatic mode, the Air Curtain system is switched on or off by external signals.

To overview

Room thermostat und room sensor:

The Air Curtain system can be set to operate depending on the room temperature.

To overview

Operating and fault message:

The control unit continuously emits a status message via potential-free signals. The operating or fault message can be processed by the BMS to monitor the Air Curtain system.

To overview

Weekly timer:

The Air Curtain system is switched on and off depending on stored switching times.

To overview

After-run function:

To avoid constantly switching the Air Curtain system on and off, a after-run time can be set to allow the unit to continue running for a short time after the door is closed.

To overview

Speed control from the BMS:

For automatic mode, a speed for the fans in the Air Curtain system can be specified by the BMS. This is done via a 0-10 V signal (or 4-20 mA signal with TCX).

To overview

Expandable with Ethernet module:

With the optional Ethernet module for the TCX control unit, all essential device functions can be controlled via the BMS. The Modbus and BACnet (TCP/IP) protocols are available for this purpose.

To overview

Multi-master function:

One control panel can be used for several independently operating Air Curtain systems. A lean solution for large entrance areas with several independent Air Curtains.

To overview

Older controllers

Do you have an older Teddington control unit? No problem – we can also provide you with the relevant operating instructions as a PDF for our models that are no longer in production. So you still have all the important information to hand.

ST3H Download TCX
ST3H-E Download TCX-E
ST5-H-WFS Download TCX
TC3 Download Download TCX
TC3-E Download Download TCX-E
TC5 Download Download TCX
TCU Download Download TCX
TLC-700 Download Download TCX
TMC-300 Download Download TCX
TMC-300-E Download Download TCX-E
TMC-500 Download Download TCX

*subject to technical inspection by providing your serial number

Industrial

Controls for our industrial Air Curtains

Robust and durable

IP54 as standard for use even in moist environments

5 standard functional scopes (S, M, L, XL, XXL) for every requirement (see table for function overview)

Teddington control system TSDM

TSDM 5 (400V)

The 5-stage TSDM 5 control unit is a powerful, flexible and robust solution with IP54 protection for the reliable operation of industrial Air Curtain systems.

Teddington control TCI

TCI-230 (230V)

The TCI-230 control unit is a robust, easy-to-integrate solution with a high degree of protection for the reliable and efficient operation of industrial Air Curtain systems.

Functions of our controllers for industrial Air Curtains

Functions S M L XL XXL
Control cabinet with protection class IP54
Manual / automatic function
Repair switch
Operating and fault signal
*
External release reset
Summer / winter changeover
Frost protection function
Fixed base load level
Adjustable base load level
After-run function automatic contact
Integrated weekly timer
Fault memory
Speed control from the BMS
Ethernet module (Modbus, BACnet)

* Indicator lights only

The most important functions explained:

Manual / automatic function:

Manual control of the Air Curtain (without an external signal such as a door contact) or in automatic mode with external signals.

To overview

Repair switch:

Repair switch installed on the switch cabinet, which interrupts the power supply to the Air Curtain and the components inside the switch cabinet.

To overview

Operating and fault signal:

The BMS can pick up and process the potential-free fault/operating signals. In addition, lights on the control cabinet indicate whether the Air Curtain is in operation or in fault mode.

To overview

External release reset:

Enabling or blocking of the Air Curtain by means of a potential-free contact. In addition, faults can be acknowledged via a potential-free contact after they have been rectified.

To overview

Summer / winter function:

A switch on the control cabinet can be used to select between summer mode (all connected heating valves are closed) and winter mode (all connected heating valves are open).

To overview

Frost protection function:

If the air intake temperature falls below 7 °C, the frost protection thermostat (optionally available) switches off the fans and opens the connected valves to prevent frost damage to the heat exchanger.

To overview

Fixed base load level:

The Air Curtain runs at fan speed 1 until the desired setpoint temperature is reached. An industrial thermostat (optionally available) is required for this function.

To overview

Adjustable base load level:

The Air Curtain runs at a desired fan speed until the desired setpoint temperature is reached. An industrial thermostat (optionally available) is required for this function.

To overview

After-run function automatic contact:

Adjustable run-on time to prevent the Air Curtain from constantly switching on and off when the door is closed and opened.

To overview

Integrated weekly timer:

The Air Curtain is switched on and off automatically according to the selected switching times.

To overview

Fault memory:

The integrated error memory shows the last error types.

To overview

Speed control from the BMS:

0-10 V signal control of the fans via the BMS in automatic mode.

To overview

Ethernet module (Modbus, BACnet):

Control of the air curtain by means of an Ethernet board (already integrated) via Modbus (TCP/IP) or BACnet.

To overview

Accessories

We offer a wide range of accessories for our Air Curtain systems

Mounting

We offer optional mounting solutions to suit the door and ceiling situation.

Sensors

Automatic control of the Air Curtain system can be realised with the aid of temperature sensors.

Valves

The hot water heat exchanger is controlled by automatic or manual valves suitable for our Air Curtain systems and control units.

Electrical accessories

An optional door contact controls the Air Curtain when it is needed.

Contact us

Get in touch with us!

Please fill out the contact form. Fields marked with * are mandatory.
We will get in touch with you as soon as possible.

Are you looking for instructions or technical data?
Your selection:
  • Air Discharge System: CONVERGO® pressure chamber nozzle system
  • Air Discharge Range:
  • Mounting position:
  • Area of application:
  • Shape:
  • Heating type:
  • Sound insulation:
  • Unit Length: Unit length made to measure
  • Fan technology: AC