E-Serie-Titel

E-Series

Powerful air curtains for commercial and retail applications

In retail and commercial environments, frequently opened entrances are part of everyday operations. Whether in supermarkets, shopping centres, furniture stores, DIY stores, car dealerships or office buildings, every time a door opens, indoor and outdoor air are exchanged. The result is draughts, energy loss and reduced comfort for customers and employees. In summer, warm outside air enters the building; in winter, valuable heating energy escapes.

The Teddington E-Series has been developed specifically for these requirements. It creates a powerful, even air stream that reliably separates the indoor and outdoor areas without restricting access for customers or staff. In this way, the E-Series helps to reduce heating and cooling costs, stabilise the indoor climate and deliver a lasting improvement in comfort around the entrance area.

Efficient shielding and flexible adjustment

The patented CONVERGO® nozzle technology ensures a high discharge range of up to 4.40 m and minimal energy consumption. Draughts, dust and insects are reliably kept away from the entrance area. The units are custom-made and available in different lengths and designs, allowing them to be flexibly adapted to all door sizes, room heights and performance requirements.

The Air Curtains can be mounted either suspended or standing. Various heating options are available for warm air curtains, including recirculating air, hot water (LTHW), electric, VRF (R410a / R32) or hybrid solutions (LTHW / electric).

The E-Series is available with both conventional AC fans and energy-saving EC fans. The latter enable infinitely variable power control and contribute to particularly efficient use. The maximum nominal volume flow is between 2,100 and 14,500 m³/h, which also effectively shields large entrance areas.

Variants for special requirements

Patented CONVERGO® nozzle technology

Precisely directed airflow for effective air separation while requiring a lower air volume than conventional air curtain systems.

Learn more

Effectiveness and reliability

Icon Made in Germany

Designed for cost-effective operation

The patented CONVERGO® pressure chamber nozzle system enables precise airflow control with a lower air volume than conventional air curtains with louvred discharge systems.

Icon Made in Germany

Quality made in Germany

Teddington air curtains are manufactured in Germany. For us, “Made in Germany” represents a high standard of quality – from precision manufacturing and careful assembly through to the final inspection of every unit.

Icon Made in Germany

Effective airflow across the full doorway

For effective separation, the air stream needs to reach the floor across the full width of the doorway.

Technical data

Air discharge system:
CONVERGO® pressure chamber nozzle system
Air discharge range:
Bis 5 m
Mounting position:
horizontal, vertical
Application:
Shop & Business
Shape:
Classic
Heating options:
Ambient (no heat), LTHW, Electric, R410a / R32 (VRF), Hybrid (water + electric)
Sound insulation:
Optional sound insulation
Unit length:
Custom unit lengths available
Fan type:
AC, EC
Convergo Düsensystem für Teddington Luftschleieranlagen

The CONVERGO® discharge system

Our patented CONVERGO® pressure chamber nozzle system is based on the Venturi principle.

Learn more

Flexible configurations for different installation requirements

The E-Series is available in a wide range of configurations for different installation requirements, including exposed wall or ceiling mounting, semi-recessed and fully recessed ceiling installation, as well as vertical installation beside the doorway.

E-Series S

Powerful air curtain for visible horizontal installation

The E-Series air curtain in housing type S is the classic solution for effective separation of indoor and outdoor air. With its frontal intake, it can be installed either directly above the door or up to the maximum recommended installation height.

E-Serie-S-200_Luftstrom-800x800

Power level 1: up to 2.90 m installation height

Technical data power level 1 E-S-1-100 E-S-1-150 E-S-1-200 E-S-1-250 E-S-1-300
Width (cm)100150200250300
Height (cm)2626262626
Depth (cm)5555555555
Max. recommended installation height (m)2.902.902.902.902.90
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 3.40 m installation height

Technical data power level 2 E-S-2-100 E-S-2-150 E-S-2-200 E-S-2-250 E-S-2-300
Width (cm)100150200250300
Height (cm)30.530.530.530.530.5
Depth (cm)62.562.562.562.562.5
Max. recommended installation height (m)3.403.403.403.403.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 4.40 m installation height

Technical data power level 3 E-S-3-100 E-S-3-150 E-S-3-200 E-S-3-250 E-S-3-300
Width (cm)100150200250300
Height (cm)43.543.543.543.543.5
Depth (cm)85.585.585.585.585.5
Max. recommended installation height (m)4.404.404.404.404.40
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a distance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series U

High-performance air curtain for visible or suspended ceiling installation

With housing type U, air is drawn into the unit from below. This configuration is suitable where a front air intake is not possible. An optional mounting frame allows the unit to be discreetly integrated into a suspended ceiling.

E-Serie-U-200_Luftstrom-800x800

Power level 1: up to 2.90 m installation height

Technical data power level 1 E-U-1-100 E-U-1-150 E-U-1-200 E-U-1-250 E-U-1-300
Width (cm)100150200250300
Height (cm)2626262626
Depth (cm)7070707070
Max. recommended installation height (m)2.902.902.902.902.90
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 3.40 m installation height

Technical data power level 2 E-U-2-100 E-U-2-150 E-U-2-200 E-U-2-250 E-U-2-300
Width (cm)100150200250300
Height (cm)30.530.530.530.530.5
Depth (cm)82.582.582.582.582.5
Max. recommended installation height (m)3.403.403.403.403.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 4.40 m installation height

Technical data power level 3 E-U-3-100 E-U-3-150 E-U-3-200 E-U-3-250 E-U-3-300
Width (cm)100150200250300
Height (cm)43.543.543.543.543.5
Depth (cm)113.5113.5113.5113.5113.5
Max. recommended installation height (m)4.404.404.404.404.40
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a distance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series UDB

High-performance air curtain for installation flush with the ceiling

The air intake from below of an air curtain is an effective solution if the device is to be integrated into the suspended ceiling. The ceiling installation frame, which is permanently welded to the air curtain, ensures that the air curtain is integrated flush with the suspended ceiling.

Teddington E-Series Housing type UDB

Power level 1: up to 2.90 m installation height

Technical data power level 1 E-UDB-1-100 E-UDB-1-150 E-UDB-1-200 E-UDB-1-250 E-UDB-1-300
Width (cm)100150200250300
Height (cm)25.525.525.525.525.5
Depth (cm)7070707070
Max. recommended installation height (m)2.902.902.902.902.90
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 3.40 m installation height

Technical data power level 2 E-UDB-2-100 E-UDB-2-150 E-UDB-2-200 E-UDB-2-250 E-UDB-2-300
Width (cm)100150200250300
Height (cm)3030303030
Depth (cm)82.582.582.582.582.5
Max. recommended installation height (m)3.403.403.403.403.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 4.40 m height

Technical data power level 3 E-UDB-3-100 E-UDB-3-150 E-UDB-3-200 E-UDB-3-250 E-UDB-3-300
Width (cm)100150200250300
Height (cm)4343434343
Depth (cm)113.5113.5113.5113.5113.5
Max. recommended installation height (m)4.404.404.404.404.40
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a distance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series Z

Powerful air curtain for suspended ceiling installation

Housing type Z is designed for concealed installation above a suspended ceiling. Only the air intake and discharge openings remain visible from below.

Teddington E-Series Housing type Z

Power level 1: up to 2.90 m installation height

Technical data power level 1 E-Z-1-100 E-Z-1-150 E-Z-1-200 E-Z-1-250 E-Z-1-300
Width (cm)100150200250300
Height (cm)3030303030
Depth (cm)7070707070
Max. recommended installation height (m)2.902.902.902.902.90
Max. nominal flow rate(m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 3.40 m installation height

Technical data Power level 2 E-Z-2-100 E-Z-2-150 E-Z-2-200 E-Z-2-250 E-Z-2-300
Width (cm)100150200250300
Height (cm)34.534.534.534.534.5
Depth (cm)82.582.582.582.582.5
Max. recommended installation height (m)3.403.403.403.403.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 4.40 m installation height

Technical data power level 3 E-Z-3-100 E-Z-3-150 E-Z-3-200 E-Z-3-250 E-Z-3-300
Width (cm)100150200250300
Height (cm)47.547.547.547.547.5
Depth (cm)113.5113.5113.5113.5113.5
Max. recommended installation height (m)4.404.404.404.404.40
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a distance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series ZS

High-performance air curtain for almost invisible suspended ceiling installation

With housing type ZS, the air intake is located above the suspended ceiling, leaving only the discharge opening visible from below. This allows the unit to be integrated particularly discreetly into the ceiling.

E-Series Housing type ZS for invisible mounting in a suspended ceiling

Power level 1: up to 2.90 m installation height

Technical data power level 1 E-ZS-1-100 E-ZS-1-150 E-ZS-1-200 E-ZS-1-250 E-ZS-1-300
Width (cm)100150200250300
Height (cm)3030303030
Depth (cm)54.554.554.554.554.5
Max. recommended installation height (m)2.902.902.902.902.90
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressue level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power Level 2: up to 3.40 m installation height

Technical data Power Level 2 E-ZS-2-100 E-ZS-2-150 E-ZS-2-200 E-ZS-2-250 E-ZS-2-300
Width (cm)100150200250300
Height (cm)34.534.534.534.534.5
Depth (cm)6262626262
Max. recommended installation height (m)3.403.403.403.403.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 4.40 m installation height

Technical data power level 3 E-ZS-3-100 E-ZS-3-150 E-ZS-3-200 E-ZS-3-250 E-ZS-3-300
Width (cm)100150200250300
Height (cm)47.547.547.547.547.5
Depth (cm)8585858585
Max. recommended installation height (m)4.404.404.404.404.40
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a distance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series R

Powerful air curtain for visible horizontal installation

The E-Series air curtain in housing type R is ta slimline solution for entrance areas with limited space above the door for entrance areas when there is little space above the door. The air intake is at the top of the air curtain so that only the rounded sheet metal on the side and the air discharge nozzle at the bottom are visible.

Teddington E-Serie Bauform R

Power level 1: up to 2.90 m installation height

Technical Data Power Level 1 E-R-1-100 E-R-1-150 E-R-1-200 E-R-1-250 E-R-1-300
Width (cm)100150200250300
Height (cm)62.562.562.562.562.5
Depth (cm)2626262626
Max. recommended installation height (m)2.902.902.902.902.90
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 3.40 m installation height

Technical data power level 2 E-R-2-100 E-R-2-150 E-R-2-200 E-R-2-250 E-R-2-300
Width (cm)100150200250300
Height (cm)71.571.571.571.571.5
Depth (cm)30.530.530.530.530.5
Max. recommended installation height (m)3.403.403.403.403.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 4.40 m installation height

Technical Data power level 3 E-R-3-100 E-R-3-150 E-R-3-200 E-R-3-250 E-R-3-300
Width (cm)100150200250300
Height (cm)9595959595
Depth (cm)43.543.543.543.543.5
Max. recommended installation height (m)4.404.404.404.404.40
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a dsitance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series RZ

High-performance air curtain for almost invisible suspended ceiling installation

The air curtain in the RZ design is a space-saving solution within the suspended ceiling. The intake area is located in the suspended ceiling at the top of the air curtain, only the outlet opening is visible below the false ceiling.

Teddington E-Series Housing type RZ for recessed installation in suspended ceilings

Power level 1: up to 2.90 m installation height

Technical data power level 1 E-RZ-1-100 E-RZ-1-150 E-RZ-1-200 E-RZ-1-250 E-RZ-1-300
Width (cm)100150200250300
Height (cm)62.562.562.562.562.5
Depth (cm)25.525.525.525.525.5
Max. recommended installation height (m)2.902.902.902.902.90
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 3.40 m installation height

Technical data power level 2 E-RZ-2-100 E-RZ-2-150 E-RZ-2-200 E-RZ-2-250 E-RZ-2-300
Width (cm)100150200250300
Height (cm)71.571.571.571.571.5
Depth (cm)3030303030
Max. recommended installation height (m)3.403.403.403.403.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 4.40 m installation height

Technical data power level 3 E-RZ-3-100 E-RZ-3-150 E-RZ-3-200 E-RZ-3-250 E-RZ-3-300
Width (cm)100150200250300
Height (cm)9595959595
Depth (cm)4343434343
Max. recommended installation height (m)4.404.404.404.404.40
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a distance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series RC

Powerful Air Curtain for visible horizontal installation

The E-Series Air Curtain in housing type RC is a slimline design with air intake from above. The even front of the unit can be customised by the customer (e.g. attachment of warning signs, etc.).

Teddington E-Serie Bauform RC

Power level 1: up to 2.90 m installation height

Technical data power level 1 E-RC-1-100 E-RC-1-150 E-RC-1-200 E-RC-1-250 E-RC-1-300
Width (cm)100150200250300
Height (cm)5959595959
Depth (cm)30.530.530.530.530.5
Max. recommended installation height (m)2.902.902.902.902.90
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 3.40 m installation height

Technical data power level 2 E-RC-2-100 E-RC-2-150 E-RC-2-200 E-RC-2-250 E-RC-2-300
Width (cm)100150200250300
Height (cm)5959595959
Depth (cm)30.530.530.530.530.5
Max. recommended installation height (m)3.403.403.403.403.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series S-V

High-performance air curtain for visible vertical installation

The E-Series S-V air curtain is the vertical version of the E-Series for positioning to the right and/or left of the door. The air intake is from the room side and creates an effective separation of indoor and outdoor air. It complements our portfolio of vertical units with an air curtain in the classic rectangular shape. Industrial doors up to a width of 5.0 m can also be effectively shielded.

Airflow Teddington E-Series S-V

Power level 1: up to 4.60 m door width

Technical data power level 1 E-S-V-1-100 E-S-V-1-150 E-S-V-1-200 E-S-V-1-250 E-S-V-1-300
Height without base plate (cm)100150200250300
Width without base plate (cm)5555555555
Depth without base plate (cm)2626262626
Dimensions of the base plate (cm)60.5 x 30 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)2.302.302.302.302.30
Max. recommended door width (both-sided standing) (m)4.604.604.604.604.60
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 5.40 m door width

Technical data power level 2 E-S-V-2-100 E-S-V-2-150 E-S-V-2-200 E-S-V-2-250 E-S-V-2-300
Height without base plate (cm)100150200250300
Width without base plate (cm)62.562.562.562.562.5
Depth without base plate (cm)30.530.530.530.530.5
Dimensions of the base plate (cm)68 x 34.5 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)2.702.702.702.702.70
Max. recommended door width (both-sided standing) (m)5.405.405.405.405.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 7.00 m door width

Technical data power level 3 E-S-V-3-100 E-S-V-3-150 E-S-V-3-200 E-S-V-3-250 E-S-V-3-300
Height without base plate (cm)100150200250300
Width without base plate (cm)85,585,585,585,585,5
Depth without base plate (cm)43,543,543,543,543,5
Dimensions of the base plate (cm)91 x 47,5 x 0,8 (B x T x H)
Max. recommended door width (one-sided standing) (m)3,503,503,503,503,50
Max. recommended door width (both-sided standing) (m)7,007,007,007,007,00
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19,319,319,319,319,3
Sound pressure level at a distance of 3 m (dB(A))56,458,459,460,461,4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series R-V

High-performance air curtain for visible vertical installation

The air curtain housing type R-V is the slim and aesthetic solution for vertical installation when there is little space in the entrance area. The air intake is on the back of the air curtain.

E-Serie-R-V-200_Luftstrom

Power level 1: up to 4.60 m door width

Technical data power level 1 E-R-V-1-100 E-R-V-1-150 E-R-V-1-200 E-R-V-1-250 E-R-V-1-300
Height without base plate (cm)100150200250300
Width without base plate (cm)2626262626
Depth without base plate (cm)62.562.562.562.562.5
Dimensions of the base plate (cm)29 x 65.5 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)2.302.302.302.302.30
Max. recommended door width (both-sided standing) (m)4.604.604.604.604.60
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 5.40 m door width

Technical data power level 2 E-R-V-2-100 E-R-V-2-150 E-R-V-2-200 E-R-V-2-250 E-R-V-2-300
Height without base plate (cm)100150200250300
Width without base plate (cm)30.530.530.530.530.5
Depth without base plate (cm)71.571.571.571.571.5
Dimensions of the base plate (cm)33.5 x 74.5 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)2.702.702.702.702.70
Max. recommended door width (both-sided standing) (m)5.405.405.405.405.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 7.00 m door width

Technical data power level 3 E-R-V-3-100 E-R-V-3-150 E-R-V-3-200 E-R-V-3-250 E-R-V-3-300
Height without base plate (cm)100150200250300
Width without base plate (cm)43.543.543.543.543.5
Depth without base plate (cm)9595959595
Dimensions of the base plate (cm)46.5 x 98 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)3.503.503.503.503.50
Max. recommended door width (both-sided standing) (m)7.007.007.007.007.00
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a distance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series RZ-V

High-performance air curtain for almost invisible vertical installation

The housing type RZ is a space-saving solution within the wall or boxing. The intake area is at the rear, so that only the discharge opening is visible.

E-Serie-RZ-V-200_Luftstrom

Power level 1: up to 4.60 m door width

Technical data power level 1 E-RZ-V-1-100 E-RZ-V-1-150 E-RZ-V-1-200 E-RZ-V-1-250 E-RZ-V-1-300
Height without base plate (cm)100150200250300
Width without base plate (cm)25.525.525.525.525.5
Depth without base plate (cm)62.562.562.562.562.5
Dimensions of the base plate (cm)31.5 x 61.5 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)2.302.302.302.302.30
Max. recommended door width (both-sided standing) (m)4.604.604.604.604.60
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 5.40 m door width

Technical data power level 2 E-RZ-V-2-100 E-RZ-V-2-150 E-RZ-V-2-200 E-RZ-V-2-250 E-RZ-V-2-300
Height without base plate (cm)100150200250300
Width without base plate (cm)3030303030
Depth without base plate (cm)71.571.571.571.571.5
Dimensions of the base plate (cm)36 x 70.5 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)2.702.702.702.702.70
Max. recommended door width (both-sided standing) (m)5.405.405.405.405.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 7.00 m door width

Technical data power level 3 E-RZ-V-3-100 E-RZ-V-3-150 E-RZ-V-3-200 E-RZ-V-3-250 E-RZ-V-3-300
Height without base plate (cm)100150200250300
Width without base plate (cm)4343434343
Depth without base plate (cm)9595959595
Dimensions of the base plate (cm)49 x 93 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)3.503.503.503.503.50
Max. recommended door width (both-sided standing) (m)7.007.007.007.007.00
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a distance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

E-Series ZS-V

High-performance air curtain for almost invisible vertical installation

The E-Series air curtain in housing type ZS-V is the vertical version of the E-Series for installation within a wall or enclosure beside the door. The air intake is located at the front of the unit within the wall, so that only the discharge nozzle is visible beside the doorway.

E-Series ZS-V vertical air curtain for recessed installation in the wall

Power level 1: up to 4.60 m door width

Technical data power level 1 E-ZS-V-1-100 E-ZS-V-1-150 E-ZS-V-1-200 E-ZS-V-1-250 E-ZS-V-1-300
Height without base plate (cm)100150200250300
Width without base plate (cm)25.525.525.525.525.5
Depth without base plate (cm)54.554.554.554.554.5
Dimensions of the base plate (cm)30.5 x 60.5 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)2.302.302.302.302.30
Max. recommended door width (both-sided standing) (m)4.604.604.604.604.60
Max. nominal flow rate (m3/h)21003150420052506300
Average air discharge speed (m/s)*14.214.214.214.214.2
Sound pressure level at a distance of 3 m (dB(A))46.648.650.652.653.6
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 2: up to 5.40 m door width

Technical data power level 2 E-ZS-V-2-100 E-ZS-V-2-150 E-ZS-V-2-200 E-ZS-V-2-250 E-ZS-V-2-300
Height without base plate (cm)100150200250300
Width without base plate (cm)3030303030
Depth without base plate (cm)62.062.062.062.062.0
Dimensions of the base plate (cm)35 x 68 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)2.702.702.702.702.70
Max. recommended door width (both-sided standing) (m)5.405.405.405.405.40
Max. nominal flow rate (m3/h)21004200525063007450
Average air discharge speed (m/s)*15.615.615.615.615.6
Sound pressure level at a distance of 3 m (dB(A))49.151.153.155.157.1
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Power level 3: up to 7.00 m door width

Technical data power level 3 E-ZS-V-3-100 E-ZS-V-3-150 E-ZS-V-3-200 E-ZS-V-3-250 E-ZS-V-3-300
Height without base plate (cm)100150200250300
Width without base plate (cm)4343434343
Depth without base plate (cm)8585858585
Dimensions of the base plate (cm)47.5 x 91 x 0.8 (W x D x H)
Max. recommended door width (one-sided standing) (m)3.503.503.503.503.50
Max. recommended door width (both-sided standing) (m)7.007.007.007.007.00
Max. nominal flow rate (m3/h)3800580085001160014500
Average air discharge speed (m/s)*19.319.319.319.319.3
Sound pressure level at a distance of 3 m (dB(A))56.458.459.460.461.4
* Data are based on measurements in accordance with ISO 27327 conducted by the Institute of Air Handling and Refrigeration (ILK) in Dresden

Designed for flexible integration

The E-Series combines a robust technical design with a high standard of manufacturing quality. A wide range of configurations and custom unit lengths allows the air curtain to be adapted to different door widths and installation requirements.

Find out more about the individual components of our E-Series.

Quality and functionality

The E-Series combines high manufacturing quality with versatile functionality.

Teddington E-Serie Türluftschleier

Wide range of accessories

A wide range of accessories is available for our air curtains – from contact switches and thermostats to temperature sensors, valves and practical mounting accessories. This allows the units to be adapted to different requirements and installation situations.

Discover our air curtain accessories
Teddington DHD Komfort-Deckenhalterung

Comfort ceiling bracket

The comfort ceiling bracket enables stable multi-point mounting of the air curtain and reduces vibrations and noise.

Learn more
Teddington AVS Aufhängeverkleidung

Suspension cover

The AVS suspension cover conceals the supply lines and threaded rods of the air curtain, ensuring a clean, high-quality appearance.

Learn more
SDA Schalldämmende Auskleidung

Sound insulation

The air curtain can also be fitted with sound-absorbing insulation to further reduce operating noise.

Learn more
RAL 7011

RAL 7011

Iron Grey

RAL 9005

RAL 9005

Deep Black

RAL 9006

RAL 9006

White Aluminium

RAL 9010

RAL 9010

Pure White

Black-grey-metallic

Black grey metallic

Metallic fine structure / matt

Farbe DB 703

DB 703

Dark Grey

Individual colours

Teddington air curtains are powder-coated to a high standard and supplied in RAL 9016 Traffic White as standard. Six additional colours are available for a small surcharge, with custom colours available on request.

Ask us about custom colours.

Application examples

Teddington TCX control unit for air curtain systems
Controller

TCX – The latest generation of air curtain controls

The TCX controller makes it easy to control and configure your Teddington air curtain system. With just a few settings, the system can be adapted to suit your individual requirements – from a single air curtain to a complex installation with multiple units.

TCX – flexible control for your Teddington air curtain system.

High process reliability

Flexible integration

Multiple control functions

Control panel with touch display

Contact us

How can we help with your project?

Tell us about your requirements using the contact form. Fields marked with * are required.

Looking for manuals or technical data?
Your selection:
  • Air discharge system: CONVERGO® pressure chamber nozzle system
  • Air discharge range:
  • Mounting position:
  • Application:
  • Shape:
  • Heating options:
  • Sound insulation:
  • Unit length: Custom unit lengths available
  • Fan type: AC